This page is printable and fits in A4 paper : >>Page setup click here
OIW-100
Oil In Water Continuous Monitoring Of Dissolved & Undissolved Oil Concentration

Oil In Water Continuous Monitoring Of Dissolved & Undissolved Oil Concentration OIW-100 
  • A sampling system, including a homogenizer, is used to allow for the monitoring of undissolved and dissolved oils .
  • The analyzer is calibrated to correlate with the EPA methods for oil & grease. (413.1)
  • three operational modes: dissolved oil, total oil, and undissolved oils.
  • A homogenizer for undissolved oils
  • Automated zeroing to compensate for nonoil substances
Specification
Application : Oil in Water
Measurements principle : UV absorbance
Detector : Diode array
Range : 0-20PPM
0-200PPM
Noise : <1% of scale
Accuracy : +/-1% of full scale, for cal oil
Temperature  
Ambient : 0-50C
sample : 1-120C
Pressure : 0-150 PSIG
Output : 4-20mA
Software  
User interface : setup auto zero, and measurement mode
Continuous : analysis and display of data
Approvals : General purpose, CE mark
  Class I,Div,II Groups B,C&D,Class I Div I Groups B,C &D;

Copyright 2008 RJ Supply and Service Co.,Ltd. 131/152 Supalai Villa, Moo 12, Soi Raminthra 40 Lane 8, Raminthra Road, Klongkum,